Powder automatic
packing machine output line inspection and troubleshooting, when the OUT1 -
OUT10 an output port without the output signal.
Please the powder
automatic packing machine breakdown is as follows: 1.
Output test into the interface.
2.
The output of the corresponding button, check the driver box up and the indicator is on.
3.
Not bright, the signal did not reach the drive box and control box, the situation was probably control box is broken.
4.
Bright, no problem with the communication between control box and driving box, this time with a voltmeter on test drive box corresponding output terminals, detect if there is a voltage output test button is pressed, a voltage: is the external wiring problem.
No voltage: drive box is broken.
5.
Powder automatic packing machine, if the external circuit problems, and then check against external circuit.
See if wiring error, or loose thread ends.
Input line inspection and troubleshooting when INT no input signal is an input.