Home  > INFO CENTER  > Products Maintainance  >  Frequency converter setting

Frequency converter setting

2019-12-26

1.Check weigher frequency converter setting

2-00:d1, frequency enter source, by external current 0-10v

2-01:d2, operated by external terminal. Keyboard STOP can work.

4-04:d2,M0: run/stop, M1: forward/reverse

1-00:60

1-01:60


2-00:d1, frequency enter source, by external current 0-10v

2-01:d2, operated by external terminal. Keyboard STOP can work.

4-04:d2,M0: run/stop, M1: forward/reverse

1-00:60

1-01:60


1-09 the first acceleration time 2

1-10 the first deceleration time 2

1-11 the second acceleration time 2

1-12 the second deceleration time 2


2 .Rotary top cone frequency converter setting

2-00:d1, frequency enter source, by external 0-10v

2-01:d2, operated by external terminal, keyboard STOP cant work.

 4-04:d2,M0: run/stopM1: forward/reverse

1-00:80

1-01:80


1-09 the first acceleration time 2

1-10 the first deceleration time 2

1-11 the second acceleration time 2

1-12 the second deceleration time 2


3.Linear combination weigher main belt frequency converter setting

2-00:d1, frequency enter source, by external current 0-10v

2-01:d1,operated by external terminal. Keyboard STOP can work.

4-04:d2,M0: run/stop, M1: forward/reverse

1-00:80

1-01:80

1-09:0.5

1-10:0.5

1-11:0.5

1-12:0.5

 

4.Linear combination weigher small belt frequency converter setting

enter password:123

F-03  1

F-06   3

F-07   1400

F-09   0.2

F-13   0.2



Chat Online 编辑模式下无法使用
Chat Online inputting...